Overview of Dry Type Transformers
Dry type transformers are increasingly popular in various industrial and commercial applications due to their safety and environmental benefits. Unlike oil-filled transformers, dry type transformers utilize air as the cooling medium, making them less prone to leaks and reducing fire risks. This makes them an ideal choice for urban areas and locations where safety is a paramount concern.

One of the critical advantages of dry type transformers is their compact design, which allows for easier installation and maintenance. They can be installed indoors or outdoors without the need for special containment measures. With advancements in technology, these transformers have become more efficient, providing reliable performance at various load conditions.
Characteristics of 4000 kVA Transformers

The 4000 kVA transformer is a significant player in the market, offering a balance between power capacity and size. This transformer type is often used in large industrial facilities, commercial buildings, and substations, delivering high levels of efficiency and reliability. The 4000 kVA rating ensures that it can handle substantial loads, making it suitable for demanding applications.
| SC(B)10 | Rated capacity (KVA) | Voltage combination(KV) | No-load losses(W) | Load losses(W) | No-load current (%) | Short-circuit impedance (%) |
| SC10-30 | 30 | 6,6.3,6.6,10,11/0.4 | 190 | 710 | 2.4 | 4.0 |
| SC10-50 | 50 | 6,6.3,6.6,10,11/0.4 | 270 | 1000 | 2.4 | 4.0 |
| SC10-80 | 80 | 6,6.3,6.6,10,11/0.4 | 370 | 1380 | 1.8 | 4.0 |
| SC10-100 | 100 | 6,6.3,6.6,10,11/0.4 | 400 | 1570 | 1.8 | 4.0 |
| SC10-125 | 125 | 6,6.3,6.6,10,11/0.4 | 470 | 1850 | 1.6 | 4.0 |
| SCB10-160 | 160 | 6,6.3,6.6,10,11/0.4 | 550 | 2130 | 1.6 | 4.0 |
| SCB10-200 | 200 | 6,6.3,6.6,10,11/0.4 | 630 | 2530 | 1.4 | 4.0 |
| SCB10-250 | 250 | 6,6.3,6.6,10,11/0.4 | 720 | 2760 | 1.4 | 4.0 |
| SCB10-315 | 315 | 6,6.3,6.6,10,11/0.4 | 880 | 3470 | 1.2 | 4.0 |
| SCB10-400 | 400 | 6,6.3,6.6,10,11/0.4 | 980 | 3990 | 1.2 | 4.0 |
| SCB10-500 | 500 | 6,6.3,6.6,10,11/0.4 | 1160 | 4880 | 1.2 | 4.0 |
| SCB10-630 | 630 | 6,6.3,6.6,10,11/0.4 | 1350 | 5880 | 1.0 | 4.0 |
| SCB10-630 | 630 | 6,6.3,6.6,10,11/0.4 | 1300 | 5960 | 1.0 | 6.0 |
| SCB10-800 | 800 | 6,6.3,6.6,10,11/0.4 | 1520 | 6960 | 1.0 | 6.0 |
| SCB10-1000 | 1000 | 6,6.3,6.6,10,11/0.4 | 1770 | 8130 | 1.0 | 6.0 |
| SCB10-1250 | 1250 | 6,6.3,6.6,10,11/0.4 | 2090 | 9690 | 1.0 | 6.0 |
| SCB10-1600 | 1600 | 6,6.3,6.6,10,11/0.4 | 2450 | 11730 | 1.0 | 6.0 |
| SCB10-2000 | 2000 | 6,6.3,6.6,10,11/0.4 | 3050 | 14450 | 0.8 | 6.0 |
| SCB10-2500 | 2500 | 6,6.3,6.6,10,11/0.4 | 3600 | 17170 | 0.8 | 6.0 |
In addition to its capacity, the 4000 kVA transformer is designed to provide excellent voltage regulation. This feature is crucial for maintaining system stability and protecting sensitive equipment from voltage fluctuations. The design includes advanced insulation materials that enhance performance and longevity, further increasing its appeal to users looking for high cost performance.
| Type | Rated capacity (KVA) | Voltage combination(KV) | No-load losses(W) | Load losses(W) | No-load Current (%) | Short-circuit impedance (%) |
| SH15-M-30 | 30 | 6,6.3,10,10.5,11/0.4 | 33 | 630 | 1.50 | 4.0 |
| SH15-M-50 | 50 | 6,6.3,10,10.5,11/0.4 | 43 | 910 | 1.20 | 4.0 |
| SH15-M-63 | 63 | 6,6.3,10,10.5,11/0.4 | 50 | 1090 | 1.10 | 4.0 |
| SH15-M-80 | 80 | 6,6.3,10,10.5,11/0.4 | 60 | 1310 | 1.00 | 4.0 |
| SH15-M-100 | 100 | 6,6.3,10,10.5,11/0.4 | 75 | 1580 | 0.90 | 4.0 |
| SH15-M-125 | 125 | 6,6.3,10,10.5,11/0.4 | 85 | 1890 | 0.80 | 4.0 |
| SH15-M-160 | 160 | 6,6.3,10,10.5,11/0.4 | 100 | 2310 | 0.60 | 4.0 |
| SH15-M-200 | 200 | 6,6.3,10,10.5,11/0.4 | 120 | 2730 | 0.60 | 4.0 |
| SH15-M-250 | 250 | 6,6.3,10,10.5,11/0.4 | 140 | 3200 | 0.60 | 4.0 |
| SH15-M-315 | 315 | 6,6.3,10,10.5,11/0.4 | 170 | 3830 | 0.50 | 4.0 |
| SH15-M-400 | 400 | 6,6.3,10,10.5,11/0.4 | 200 | 4520 | 0.50 | 4.0 |
| SH15-M-500 | 500 | 6,6.3,10,10.5,11/0.4 | 240 | 5140 | 0.50 | 4.0 |
| SH15-M-630 | 630 | 6,6.3,10,10.5,11/0.4 | 320 | 6200 | 0.30 | 4.5 |
| SH15-M-800 | 800 | 6,6.3,10,10.5,11/0.4 | 380 | 7500 | 0.30 | 4.5 |
| SH15-M-1000 | 1000 | 6,6.3,10,10.5,11/0.4 | 450 | 10300 | 0.30 | 4.5 |
| SH15-M-1250 | 1250 | 6,6.3,10,10.5,11/0.4 | 530 | 12000 | 0.20 | 4.5 |
| SH15-M-1600 | 1600 | 6,6.3,10,10.5,11/0.4 | 630 | 14500 | 0.20 | 4.5 |
| SH15-M-2000 | 2000 | 6,6.3,10,10.5,11/0.4 | 750 | 18300 | 0.20 | 5.0 |
| SH15-M-2500 | 2500 | 6,6.3,10,10.5,11/0.4 | 900 | 21200 | 0.20 | 5.0 |
Advantages of Choosing a China Maker
Choosing a Chinese manufacturer for dry type transformers, especially the 4000 kVA models, offers several advantages. Chinese manufacturers have made significant strides in improving production quality while keeping costs competitive. As a result, buyers can obtain high-quality transformers at a fraction of the price compared to Western counterparts.
Moreover, many Chinese manufacturers are equipped with advanced technology and skilled labor, ensuring that the transformers meet international standards. This combination of affordability and quality makes them an attractive option for companies looking to maximize their investment. With the growing global demand for energy-efficient solutions, opting for a Chinese maker can lead to significant savings without compromising on performance.