Table of Contents
Understanding Auxiliary Transformers and Medium Voltage Transformers
| SC(B)11 | Rated capacity (KVA) | Voltage combination(KV) | No-load losses(W) | Load losses(W) | No-load current (%) | Short-circuit impedance (%) |
| SC11-30 | 30 | 6,6.3,6.6,10,11/0.4 | 180 | 710 | 2.4 | 4.0 |
| SC11-50 | 50 | 6,6.3,6.6,10,11/0.4 | 250 | 1000 | 2.4 | 4.0 |
| SC11-80 | 80 | 6,6.3,6.6,10,11/0.4 | 340 | 1380 | 1.8 | 4.0 |
| SC11-100 | 100 | 6,6.3,6.6,10,11/0.4 | 360 | 1570 | 1.8 | 4.0 |
| SC11-125 | 125 | 6,6.3,6.6,10,11/0.4 | 420 | 1850 | 1.6 | 4.0 |
| SCB11-160 | 160 | 6,6.3,6.6,10,11/0.4 | 490 | 2130 | 1.6 | 4.0 |
| SCB11-200 | 200 | 6,6.3,6.6,10,11/0.4 | 560 | 2530 | 1.4 | 4.0 |
| SCB11-250 | 250 | 6,6.3,6.6,10,11/0.4 | 650 | 2760 | 1.4 | 4.0 |
| SCB11-315 | 315 | 6,6.3,6.6,10,11/0.4 | 790 | 3470 | 1.2 | 4.0 |
| SCB11-400 | 400 | 6,6.3,6.6,10,11/0.4 | 880 | 3990 | 1.2 | 4.0 |
| SCB11-500 | 500 | 6,6.3,6.6,10,11/0.4 | 1050 | 4880 | 1.2 | 4.0 |
| SCB11-630 | 630 | 6,6.3,6.6,10,11/0.4 | 1210 | 5880 | 1.0 | 4.0 |
| SCB11-630 | 630 | 6,6.3,6.6,10,11/0.4 | 1170 | 5960 | 1.0 | 6.0 |
| SCB11-800 | 800 | 6,6.3,6.6,10,11/0.4 | 1370 | 6960 | 1.0 | 6.0 |
| SCB11-1000 | 1000 | 6,6.3,6.6,10,11/0.4 | 1590 | 8130 | 1.0 | 6.0 |
| SCB11-1250 | 1250 | 6,6.3,6.6,10,11/0.4 | 1880 | 9690 | 1.0 | 6.0 |
| SCB11-1600 | 1600 | 6,6.3,6.6,10,11/0.4 | 2210 | 11730 | 1.0 | 6.0 |
| SCB11-2000 | 2000 | 6,6.3,6.6,10,11/0.4 | 2720 | 14450 | 0.8 | 6.0 |
| SCB11-2500 | 2500 | 6,6.3,6.6,10,11/0.4 | 3200 | 17170 | 0.8 | 6.0 |
Auxiliary transformers are essential components in various electrical systems, providing power to auxiliary equipment. These transformers play a critical role in ensuring the smooth operation of larger transformer units by supplying power to control systems, cooling systems, and other ancillary devices. In many cases, these transformers are designed to operate at medium voltage levels, making them suitable for a wide range of industrial applications.
Medium voltage transformers typically operate within the voltage range of 1kV to 35kV. Their primary function is to step down the higher transmission voltages to lower levels that can be used by end users. This type of transformer is crucial in substations and industrial facilities, as it ensures the safe and efficient distribution of electricity to various loads. A good understanding of their specifications and operational characteristics is necessary when selecting the right unit for a specific application.
Choosing the Best Supplier for Transformers in China
When looking for a reliable supplier for auxiliary and medium voltage transformers, China’s manufacturing sector offers a plethora of options. Many factories specialize in producing high-quality transformers that meet international standards. However, it is crucial to conduct thorough research and due diligence before making a selection, as not all suppliers can guarantee the same level of quality and service.

One way to evaluate potential suppliers is by reviewing customer testimonials and case studies. Additionally, watching videos showcasing the manufacturing process and product features can provide insights into the supplier’s capabilities. By taking the time to understand the available options, you can ensure that you partner with a reputable factory that consistently delivers quality products.
| Type | Rated capacity (KVA) | Voltage combination(KV) | No-load losses(W) | Load losses(W) | No-load current (%) | Short-circuit impedance (%) |
| SZ11-2000 | 2000 | 33,35/6.3,6.6,10.5,11 | 2300 | 19240 | 0.80 | 6.5 |
| SZ11-2500 | 2500 | 33,35/6.3,6.6,10.5,11 | 2720 | 20640 | 0.80 | 6.5 |
| SZ11-3150 | 3150 | 33,35/6.3,6.6,10.5,11 | 3230 | 24710 | 0.72 | 7.0 |
| SZ11-4000 | 4000 | 33,35/6.3,6.6,10.5,11 | 3870 | 29160 | 0.72 | 7.0 |
| SZ11-5000 | 5000 | 33,35/6.3,6.6,10.5,11 | 4640 | 34200 | 0.68 | 7.0 |
| SZ11-6300 | 6300 | 33,35/6.3,6.6,10.5,11 | 5630 | 36800 | 0.68 | 7.5 |
| SZ11-8000 | 8000 | 33,35/6.3,6.6,10.5,11 | 7870 | 40600 | 0.60 | 7.5 |
| SZ11-10000 | 10000 | 33,35/6.3,6.6,10.5,11 | 9280 | 48100 | 0.60 | 7.5 |
| SZ11-12500 | 12500 | 33,35/6.3,6.6,10.5,11 | 10940 | 56900 | 0.56 | 8.0 |
| SZ11-16000 | 16000 | 33,35/6.3,6.6,10.5,11 | 13170 | 70300 | 0.54 | 8.0 |
| SZ11-20000 | 20000 | 33,35/6.3,6.6,10.5,11 | 15570 | 82800 | 0.54 | 8.0 |
The Importance of Quality Assurance in Transformer Manufacturing
Quality assurance is paramount in the production of auxiliary transformers and medium voltage transformers. Factories in China often implement stringent quality control measures to ensure that each unit meets specific performance criteria. This involves rigorous testing and inspection processes throughout the manufacturing cycle to identify any potential defects early on.
<pInvesting in high-quality transformers is essential as it directly impacts the reliability and safety of electrical systems. A well-manufactured transformer will not only perform efficiently but also have a longer lifespan, reducing the need for frequent replacements or repairs. Therefore, working with a supplier that prioritizes quality assurance is vital for any project requiring transformers.